Chapter 4: Commands for CLI configuration
ipv6 mld snooping query-max-response-time
Command:
ipv6 mld snooping query-max-response-time <IpmcQi : 1-31744>
ipv6
IPv6 configuration commands
mld
Multicast Listener Discovery
snooping
Snooping MLD
query-max-response-time
Query Response Interval in tenths of seconds
<IpmcQri : 0-31744>
0 - 31744 tenths of seconds
Default:
125
Usage Guide:
To configure
Querier-interval of
MLD snooping
for specific VLAN
Example:
To configure
Querier-interval
(60 seconds)
of
MLD snooping
for
VLAN X
Switch# configure terminal
Switch (config)#
interface vlan X
Switch (config-if-vlan)#
ipv6 mld snooping query-max-
response-time 600
ipv6 mld snooping robustness-variable
Command:
ipv6 mld snooping robustness-variable <IpmcRv : 1-255>
ipv6
IPv6 configuration commands
mld
Multicast Listener Discovery
snooping
Snooping MLD
robustness-variable
Robustness Variable
<IpmcRv : 1-255>
Packet loss tolerance count from 1 to 255
Default:
2
Usage Guide:
To configure
Robustness Variable of
MLD snooping
for specific VLAN
Example:
To configure
Robustness Variable
(88)
of
MLD snooping
for
VLAN X
Switch# configure terminal
Switch (config)#
interface vlan X
Switch (config-if-vlan)#
ipv6 mld snooping robustness-variable
88
ipv6 mld snooping unsolicited-report-interval
Command:
ipv6 mld snooping unsolicited-report-interval <IpmcUri : 0-31744>
ipv6
IPv6 configuration commands
mld
Multicast Listener Discovery
NS3500-24T-4C Managed Switch Command Guide
127