Chapter 4: Commands for CLI configuration
<Instance>
The MEP instance number.
tst
Test Signal
<Prio : 0-7>
Priority in case of tagged OAM. In the EVC domain this is the COS-
ID.
dei
Drop Eligible Indicator in case of tagged OAM.
mep-id
Peer MEP-ID for unicast TST. The MAC is taken from peer MEP MAC
database.
<Mepid : uint>
Peer MEP-ID value
sequence
Enable sequence number in TST PDU
all-one
Test pattern is set to all one.
all-zero
Test pattern is set to all zero.
one-zero
Test pattern is set to 10101010.
rate
The TST frame transmission bit rate - in Mega bits pr. second. Limit on
Caracal is 400 Mbps. Limit on Serval is 1Gbps. This is the bit rate of
a standard frame without any encapsulation. If 1 Mbps rate is
selected in a EVC MEP, the added tag will give a hi
<Rate : uint>
Transmission rate value
size
The TST frame size. This is entered as the wanted size (in bytes) of a un-
tagged frame containing TST OAM PDU - including CRC (four bytes).
Example when 'Size' = 64 => Un-tagged frame size = DMAC(6) +
SMAC(6) + TYPE(2) + TST PDU LENGTH(46) + CRC(4) = 64
<Size : uint>
Frame size value
Default:
Usage Guide:
To enable
Test Signal
of
MEP
.
Example:
To enable
Test Signal
of
MEP 1
as below table
Switch# configure terminal
Switch (config)#
mep 1 tst 3 dei mep-id 2 sequence one-zero
rate 10 size 68
mep <Instance> up
Command:
mep <Instance> [mip]
up domain { port | evc | vlan } [ vid
<vid> ] flow <flow> level <level> interface <port_type> <port>
mep
Maintenance Entity Point
<Instance>
The MEP instance number.
mip
This MEP instance is a half-MIP
up
This MEP is a Up-MEP
domain
The domain of the MEP
evc
This MEP is a EVC domain MEP.
port
This MEP is a Port domain MEP.
NS3500-24T-4C Managed Switch Command Guide
181