Chapter 4: Commands for CLI configuration
To enable
Querier-election of
IGMP snooping
for specific VLAN
Example:
To enable
Querier-election of
IGMP snooping
for
VLAN X
Switch# configure terminal
Switch (config)#
interface vlan X
Switch (config-if-vlan)#
ip igmp snooping querier election
ip igmp snooping query-interval
Command:
ip igmp snooping query-interval <IpmcQi : 1-31744>
ip
Interface Internet Protocol config commands
igmp
Internet Group Management Protocol
snooping
Snooping IGMP
query-interval
Query Interval in seconds
<IpmcQi : 1-31744>
1 - 31744 seconds
Default:
125
Usage Guide:
To configure
Querier-interval of
IGMP snooping
for specific VLAN
Example:
To configure
Querier-interval
(600 seconds)
of
IGMP snooping
for
VLAN X
Switch# configure terminal
Switch (config)#
interface vlan X
Switch (config-if-vlan)#
ip igmp snooping query-interval 600
ip igmp snooping query-max-response-time
Command:
ip igmp snooping query-max-response-time <IpmcQi : 1-
31744>
ip
Interface Internet Protocol config commands
igmp
Internet Group Management Protocol
snooping
Snooping IGMP
query-max-response-time
Query Response Interval in tenths of seconds
<IpmcQri : 0-31744>
0 - 31744 tenths of seconds
Default:
125
Usage Guide:
To configure
Querier-interval of
IGMP snooping
for specific VLAN
Example:
To configure
Querier-interval
(60 seconds)
of
IGMP snooping
for
VLAN X
Switch# configure terminal
Switch (config)#
interface vlan X
Switch (config-if-vlan)#
ip igmp snooping query-max-response-time 600
122
NS3500-24T-4C Managed Switch Command Guide