Chapter 4: Commands for CLI configuration
sflow timeout
Command:
sflow timeout <timeout>
sflow
Statistics flow
timeout
Receiver timeout measured in seconds. The switch decrements the
timeout once per second, and as long as it is non-zero, the receiver
receives samples. Once the timeout reaches 0, the receiver and all its
configuration is reset to defaults.
<timeout: 0-2147483647>
Number of seconds
Default:
None
Usage Guide:
To configure the
Collector timeout
of
sFlow
Example:
To configure the
Collector timeout
(555 seconds)
of
sFlow
Switch# configure terminal
Switch (config)#
sflow timeout 555
sfp temperature-threshold
Command:
sfp temperature-threshold <0-100>
sfp temperature-threshold
Set a lower high temperature threshold for the
secondary temperature alarm in
degrees C.
<0-100>
Specifies the new threshold temperature.
Default:
None
Usage Guide:
To configure the
SFP temperature-threshold
of
sFlow
Example:
To configure the
SFP temperature-threshold
(55 degrees C)
of
sFlow
Switch# configure terminal
Switch (config)#
sfp temperature-threshold 55
snmp-server
Command:
snmp-server
snmp-server
Set SNMP server's configurations
Default:
Enabled
NS3500-24T-4C Managed Switch Command Guide
217