Alarm
Note before alarm setup, you will need to properly connect alarm input and output
device, send address and receive address. Click save, confirm current setup.
Alarm setup includes the following items. See Figure 7-36.
Alarm in: Select channel number.
Event type: There are two types: local input/network input.
Type: Normal open or normal close.
PTZ activation: PTZ activation: Here, you can relate a PTZ preset to a detection
event. PTZ presets include functions such as go to a preset location, being a tour
or pattern, etc. Click
“
select
”
, and you will see an interface as shown in
Error!
Reference source not found.
.
Period: Click the set button, and you will see an interface as shown in Figure 7-36.
Here you can set business days and non-business days.
Show message: the system can provide pop up notifications on the local screen if
this function is enabled.
Record channel: you can select any channel to record alarm video (or multiple
channels). Make sure alarm recording is configured in the schedule menu (Main
Menu
Setting
Schedule). Also be sure to select schedule record in the manual
record menu(Main Menu
Advance
Manual Record).
Latch: when detection is complete, the auto trigger continues detecting for a
specified time. The value ranges from 10-300 seconds.
Tour: Here you can enable the tour function once an alarm occurs. It is a one-
window tour (full-screen): Please go to chapter 5.3.9 Display for tour interval
setup.
Figure 7-36
Summary of Contents for Max 16
Page 1: ... 2009 IC Realtime Inc 1 Standalone DVR User s Manual Max 8 16 ...
Page 29: ... 2009 IC Realtime Inc 29 Figure 3 11 ...
Page 47: ... 2009 IC Realtime Inc 47 Figure 4 21 Figure 4 22 Figure 4 23 Figure 4 24 ...
Page 55: ... 2009 IC Realtime Inc 55 Figure 4 39 ...
Page 111: ... 2009 IC Realtime Inc 111 Figure 7 38 Figure 7 39 ...
Page 112: ... 2009 IC Realtime Inc 112 Figure 7 40 Figure 7 41 Figure 7 42 ...
Page 128: ... 2009 IC Realtime Inc 128 ...
Page 140: ... 2009 IC Realtime Inc 140 ...