3. Operation
Fieldbus Communication
165
RCP6S
3.9.6 PROFINET-IO
Front Side Top Side
STATUS-0
STATUS-1
{
: Illuminating, ×: OFF, : Flashing
Name
Panel
State
Display Color
Remarks
Green (Illuminating)
Communication established, in RUN status
Green (Flashing)
Communication established, in STOP status
STATUS-1
NS
× (OFF)
Power is OFF, No connection
Green (Illuminating)
In the normal operation
Green (Flashing 1)
Diagnosis even exists
Green (Flashing 2)
Engineering tool identifying nodes
Orange (Flashing)
In serious malfunction (EXCEPTION) status
Orange (Flashing 1) Configuration error
Orange (Flashing 2) IP address error (IP address unset)
Orange (Flashing 3) Station name error (Station name not
established)
Orange (Flashing 4) Internal critical malfunction error
STATUS-0
MS
(Note1)
× (OFF)
Power turned OFF, module setup/initial status
Note 1
The continues to flash for number of times stated beside the star mark ( ) in
every 0.25sec.
3
1
2
4
1
2
ME0349-4B