3. Operation
Fieldbus Communication
112
RCP6S
PLC Output (m is PLC output top word address for each axis number)
Address m
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4 b3 b2 b1
b0
Target Position
(Lower word)
Address m+1
b15 b14 b13 b12 b11 b10 b9
b8
b7
b6
b5
b4 b3 b2 b1
b0
Target Position
(Upper word)
(Note) If the target position is a negative value, it is input by a two’s complement.
Address m+2
b15 b14 b13 b12 b11 b10 b9
b8
b7
b6
b5
b4 b3 b2 b1
b0
Positioning Width
(Lower word)
32,768
16,384
8,192
4,096
2,048
1,024
512
256
128
64
32
16
8
4
2
1
Address m+3
b15 b14 b13 b12 b11 b10 b9
b8
b7
b6
b5
b4 b3 b2 b1
b0
Positioning Width
(Upper word)
–
–
–
–
–
–
–
–
–
–
–
–
524,288
262,144
131,072
65,536
Address m+4
b15 b14 b13 b12 b11 b10 b9
b8
b7
b6
b5
b4 b3 b2 b1
b0
Command Speed
32,768
16,384
8,192
4,096
2,048
1,024
512
256
128
64
32
16
8
4
2
1
Address m+5
b15 b14 b13 b12 b11 b10 b9
b8
b7
b6
b5
b4 b3 b2 b1
b0
Acceleration/
Deceleration
–
–
–
–
–
–
–
256
128
64
32
16
8
4
2
1
Address m+6
b15 b14 b13 b12 b11 b10 b9
b8
b7
b6
b5
b4 b3 b2 b1
b0
Pressing Current
Limit Value
–
–
–
–
–
–
–
256
128
64
32
16
8
4
2
1
Address m+7
b15 b14 b13 b12 b11 b10 b9
b8
b7
b6
b5
b4 b3 b2 b1
b0
Control Signal
BKRL
INC
DIR
PUSH
–
–
–
JOG+
JOG-
JVEL
JISL
SO
N
RES
STP
HOME
CSTR
1 word = 16 bit
3.4.5
ME0349-4B
Summary of Contents for RCM-P6AC
Page 2: ......
Page 9: ...Fieldbus Communication RCP6S ME0349 4B ...
Page 32: ...Fieldbus Communication 20 RCP6S ME0349 4B ...
Page 86: ...2 Wiring Fieldbus Communication 74 RCP6S ME0349 4B ...
Page 178: ...3 Operation Fieldbus Communication 166 RCP6S ME0349 4B ...
Page 184: ...4 Vibration Suppress Control Function Fieldbus Communication 172 RCP6S ME0349 4B ...
Page 192: ...6 Power saving Function Fieldbus Communication 180 RCP6S ME0349 4B ...
Page 196: ...7 Absolute Reset Fieldbus Communication 184 RCP6S ME0349 4B ...
Page 284: ......
Page 285: ......