1. Specifications Check
Fieldbus Communication
35
RCP6S
1.4.6 Specifications of PROFINET-IO Interface
Item
Specification
Communication Protocol
IEC61158 (IEEE802.3), IEC61784
Baud Rate
100Mbps
Number of Occupied Bytes
3.4.1 PLC Address Construction by each Operation Mode
Communication Cable Length
Distance between each segment: 100m Max.
Number of Connection
Follows master unit
Available Node Addresses for Setting 0.0.0.0 to 255.255.255.255
Communications Cable
(Note 1)
Category 5 or more
(Double shielded cable braided with aluminum foil recommended)
Connector
RJ45 connector × 1pc
GSDML File Version
Ver 2.3
Note 1 Prepare separately for the communication cable.