3. Operation
Fieldbus Communication
125
RCP6S
(2) Input and Output Signal Assignment for each Axis
The I/O signals for each axis consists of 2-word for each I/O bit register.
● The control signals and status signals are ON/OFF signals in units of bit.
● For the indicated position number and complete position number, 1-word (16-bit) binary data
is available and values from 0 to 15 can be used.
● The current position is the binary data in 1 word (16 bits), and can deal with numbers from
-32768 to +32767 (unit: 0.1mm) in PLC. Negative numbers are to be dealt with two’s
complement.
Caution:
Set the operational condition in advance with using a teaching tool such as PC software in the
position number to be used. Selecting a position number with no setting conducted will
generate the alarm code 0A2 “Position Data Error”.
PLC Output (m is PLC output top word address for each axis number)
Address m
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4 b3 b2 b1
b0
Specified
Position No.
–
–
–
–
–
–
–
–
–
–
–
–
PC
8
PC
4
PC
2
PC
1
Address m+1
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4 b3 b2 b1
b0
Control Signal
BKRL
–
–
–
–
–
–
JOG+
JOG-
JVEL
JISL
SO
N
RES
STP
HOME
CSTR
PLC Input (m is PLC input top word address for each axis number)
Address m
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4 b3 b2 b1
b0
Current Position
(Note) If the target position is a negative value, it is indicated by a two’s complement.
Address m+1
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4 b3 b2 b1
b0
Status Signal/
Completed
Position No.
EMG
S
CRDY
ZONE
2
ZONE
1
PM8
PM4
PM2
PM1
MEND
ALML
PSFL
SV
ALM
MO
VE
HEND
PE
N
D
1 word = 16 bit
1 word = 16 bit
3.4.8
ME0349-4B
Summary of Contents for RCM-P6AC
Page 2: ......
Page 9: ...Fieldbus Communication RCP6S ME0349 4B ...
Page 32: ...Fieldbus Communication 20 RCP6S ME0349 4B ...
Page 86: ...2 Wiring Fieldbus Communication 74 RCP6S ME0349 4B ...
Page 178: ...3 Operation Fieldbus Communication 166 RCP6S ME0349 4B ...
Page 184: ...4 Vibration Suppress Control Function Fieldbus Communication 172 RCP6S ME0349 4B ...
Page 192: ...6 Power saving Function Fieldbus Communication 180 RCP6S ME0349 4B ...
Page 196: ...7 Absolute Reset Fieldbus Communication 184 RCP6S ME0349 4B ...
Page 284: ......
Page 285: ......