8. Parameter
Fieldbus Communication
212
RCP6S
[51] Monitoring mode selection (Parameter No.112)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
112 Monitoring Mode Selection
FMNT
-
0: Unused
1: Monitor Function 1
2: Monitor Function 2
3: Monitor Function 3
1
The controller can be connected with PC software to monitor the servo.
This parameter allows you to select a monitoring mode function (number of channels in the
servomotor).
Check the Instruction Manual of the RC PC software for details.
Set Value
Description
0
Unused
1
Sets the 4CH record mode.
2
Sets the 8CH record mode.
3
Sets the 2CH record mode.
[52] Monitoring period (Parameter No.113)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
113 Monitoring Period
FMNT
msec
1 to 60000
1
This is the parameter to set up the frequency to the initial setting
(Note 1)
of time to obtain data
(Sampling Frequency) when the monitoring mode is selected.
By setting the value in this parameter bigger, the frequency of data obtaining can be made
longer.
It is set to 1msec in the initial setting. Up to 60000msec can be set.
1msec frequency setting
60000msec frequency setting
Up to 2.048 seconds in 4CH
record mode
Up to 34 hours 8 minutes in 4CH
record mode
Up to 1.024 seconds in 8CH
record mode
Up to 17 hours 4 minutes in 8CH
record mode
Up to 4.096 seconds in 2CH
record mode
Up to 68 hours 16 minutes in 2CH
record mode
Note 1 The sampling period can be changed in the RC PC software.
ME0349-4B
Summary of Contents for RCM-P6AC
Page 2: ......
Page 9: ...Fieldbus Communication RCP6S ME0349 4B ...
Page 32: ...Fieldbus Communication 20 RCP6S ME0349 4B ...
Page 86: ...2 Wiring Fieldbus Communication 74 RCP6S ME0349 4B ...
Page 178: ...3 Operation Fieldbus Communication 166 RCP6S ME0349 4B ...
Page 184: ...4 Vibration Suppress Control Function Fieldbus Communication 172 RCP6S ME0349 4B ...
Page 192: ...6 Power saving Function Fieldbus Communication 180 RCP6S ME0349 4B ...
Page 196: ...7 Absolute Reset Fieldbus Communication 184 RCP6S ME0349 4B ...
Page 284: ......
Page 285: ......