9.
Troubleshooting
Fieldbus Communication
234
RCP6S
9.3.2 Connection Unit Control Power Voltage Drop Alarm
When Gateway Unit Version V0003 or later and also Hub Unit Version V0003 or later, the gateway
unit monitors the control power voltage of the hub unit, and it displays “8B0 Connection Unit Control
Power Voltage Drop” when the voltage has dropped.
There is no Hub Unit Version V0002.
Hub Unit SYS LED Display
The display status of SYS LED lamp when the voltage has recovered to the normal
condition from control power voltage drop differs depending on the version of the hub unit.
There is no Hub Unit Version V0002.
Gateway Unit Version
V0002 and earlier
V0003 and later
V0001
.
No displayed
No displayed
Hub Unit
Version
V0003 and
later
No displayed
8B0 displayed
Control Power Voltage (Monitor Power Voltage in Normal)
Hub Unit
Version
In Normal
When Dropped
Recovered to
Normal after Drop
V0001
.
Green
Illuminating
Green
Flashing
Red
Illuminating
Green
Illuminating
Green
Flashing
V0003 and
later
Green
Illuminating
Green
Flashing
Red
Illuminating
Red
Illuminating
Hub Unit
Green Illuminating : Ready Status
Green Flashing
: Standby with Communication Established
Red Illuminating : Control / Motor Power Voltage Drop
SYS LED
ME0349-4B
Summary of Contents for RCM-P6AC
Page 2: ......
Page 9: ...Fieldbus Communication RCP6S ME0349 4B ...
Page 32: ...Fieldbus Communication 20 RCP6S ME0349 4B ...
Page 86: ...2 Wiring Fieldbus Communication 74 RCP6S ME0349 4B ...
Page 178: ...3 Operation Fieldbus Communication 166 RCP6S ME0349 4B ...
Page 184: ...4 Vibration Suppress Control Function Fieldbus Communication 172 RCP6S ME0349 4B ...
Page 192: ...6 Power saving Function Fieldbus Communication 180 RCP6S ME0349 4B ...
Page 196: ...7 Absolute Reset Fieldbus Communication 184 RCP6S ME0349 4B ...
Page 284: ......
Page 285: ......