Module
Name
Parameter
Name
Setting
MU
MUNNatIP
Northbound IP address of the IVS1800, which
must be the same as the NAT-mapped IP
address configured on the firewall.
NatRtspServer
Port
NAT port number of the IVS1800 MU, which
must be the same as the NAT mapped port
number configured on the firewall.
The default port number of the MU before
mapping is 554.
NatRtspTlsSer
verPort
TLS NAT port number of the IVS1800 MU,
which must be the same as the NAT mapped
port number configured on the firewall.
The default TLS port number of the MU before
mapping is 322.
Step 7 (Optional) Configure the IVS1800 to synchronize time with the NTP server. Choose
Local Configuration > Server configuration and configure the server time
information.
Table 5-41 Parameter description
Parameter
Setting
The NTP clock source server
Indicates whether the NTP clock
source server is specified for time
synchronization.
● Select Yes if an NTP server is
configured onsite.
● Select No If no NTP server is
configured onsite.
NTP server IP
Indicates the IP address of the NTP
clock source server. After this
parameter is specified, the server
synchronizes the time to this clock
source.
●
If an NTP server is configured onsite, synchronize the time with the NTP
server.
●
If no NTP server is configured onsite, manually configure the server time:
Change Timezone config and Time config based on the time of the source
server to be synchronized.
Step 8 Configure cameras to synchronize time with the IVS1800.
The camera NTP synchronization function for the server is disabled by default. The
camera NTP synchronization function needs to be enabled for the server that
FusionModule2000-S Smart Modular Data Center
User Manual
5 Power-On Commissioning
Issue 03 (2021-07-15)
Copyright © Huawei Technologies Co., Ltd.
199