276
HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide
Audible Beeps: None
Possible Cause: The battery charge is below 75 percent. Posted writes are
disabled.
Action: Replace the array accelerator board if the batteries do not recharge
within 36 powered-on hours.
1795-Drive Array - Array Accelerator Configuration Error...
...Data does not correspond to this drive array. Array Accelerator is temporarily disabled.
Audible Beeps: None
Possible Cause: Power was interrupted while data was in the array accelerator
memory, or the data stored in the array accelerator does not correspond to this
drive array.
Action: Match the array accelerator to the correct drive array, or run ACU
("Array Configuration Utility" on page
115
) to clear the data in the array
accelerator.
1796-Drive Array - Array Accelerator Not Responding...
...Array Accelerator is temporarily disabled.
Audible Beeps: None
Possible Cause: Array accelerator is defective or is missing. Depending on the
array controller model, the cache may be disabled or the controller might not be
usable until this problem is corrected.
Action:
1. Reseat the array accelerator daughter board if the connector is loose.
2. If the problem persists, replace the board.
1797-Drive Array - Array Accelerator Read Error Occurred...
...Data in Array Accelerator has been lost.
Array Accelerator is disabled.
Summary of Contents for ML370 - ProLiant - G3
Page 8: ......
Page 52: ......
Page 85: ...Hardware options installation 85 2 Release the retaining clip 3 Install the expansion board ...
Page 110: ......
Page 130: ......
Page 138: ...138 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 140: ...140 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 143: ...Troubleshooting 143 ...
Page 145: ...Troubleshooting 145 ...
Page 147: ...Troubleshooting 147 ...
Page 150: ...150 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 292: ......