272
HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide
•
Audible Beeps: None
•
−
•
Replace the failed drive and press the F1 key to rebuild the array. If the drive
rebuild is not successful or is aborted because the system rebooted before the
rebuild of the drive completed, another version of the 1786 POST error
message will be displayed. Refer to the following message.
1786-Slot 1 Drive Array Recovery Needed. Automatic Data Recovery
Previously Aborted!...
...The following SCSI drive(s) need Automatic Data Recovery: SCSI Port Y: SCSI ID Z
Select F1 to retry Automatic Data Recovery to drive. Select F2 to continue without starting
Automatic Data Recovery.
Possible Cause: System is in Interim Data Recovery Mode and a failed or
replacement drive has not yet been rebuilt. This message is displayed if the F2
key was pressed during a previous boot or if the F1 key was pressed during a
previous boot and the system rebooted before the rebuild of the drive completed.
Action:
Perform one of the suggested actions:
−
Press the F1 key to retry Automatic Data Recovery to the drive. Data
will be automatically restored to drive X when a failed drive has been
replaced, or to the original drive if it is working again without errors.
Press the F2 key to continue without recovery of data to the drive. The
failed drive will not be rebuilt and the system will continue to operate in
a failed state of Interim Data Recovery Mode.
If drive recovery is not successful, run ADU ("Array Diagnostic Utility" on
page
126
) for more information.
−
If the replacement drive failed, replace with another drive.
−
If the rebuild was aborted due to a read error from another physical drive
in the array, back up all readable data on the array, run ADU, and then
restore the data.
1787-Drive Array Operating in Interim Recovery Mode...
...Physical drive replacement needed: Drive X
Summary of Contents for ML370 - ProLiant - G3
Page 8: ......
Page 52: ......
Page 85: ...Hardware options installation 85 2 Release the retaining clip 3 Install the expansion board ...
Page 110: ......
Page 130: ......
Page 138: ...138 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 140: ...140 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 143: ...Troubleshooting 143 ...
Page 145: ...Troubleshooting 145 ...
Page 147: ...Troubleshooting 147 ...
Page 150: ...150 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 292: ......