HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide
System LED and
Color
Internal Health
LED Color
Status
Processor failure,
socket X (Amber)
Red
One or more of the following conditions may exist:
•
•
•
Processor in socket X has failed.
Processor
X is not installed in the socket.
ROM detected a failed processor during POST.
Amber
Processor in socket X is in a pre-failure condition.
PPM failure, slot X
(Amber)
Red
•
•
PPM in slot X has failed.
PPM is not installed in slot X, but the corresponding
processor is installed.
DIMM failure, slot X
(Amber)
Red
•
•
DIMM in slot X has failed.
DIMM has experienced a multi-bit error.
Amber
•
•
DIMM in slot X has reached single-bit correctable
error threshold.
DIMM in slot X is in a pre-failure condition.
DIMM bank error (all
slots in one bank,
Amber)
Red
The bank is not populated entirely or DIMMs do not all
match within the bank.
DIMM failure (all
slots, Amber)
Red
•
•
No valid or usable memory is installed in the system.
The banks are not populated in the correct order.
System temperature
alert (Amber)
Red
System temperature has exceeded OS cautionary level
or critical hardware level.
Fan (Amber)
Red
A required fan has failed.
Amber
A redundant fan has failed.
Power supply
backplane failure
(Amber)
Red
The power supply backplane has failed.
Summary of Contents for ML370 - ProLiant - G3
Page 8: ......
Page 52: ......
Page 85: ...Hardware options installation 85 2 Release the retaining clip 3 Install the expansion board ...
Page 110: ......
Page 130: ......
Page 138: ...138 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 140: ...140 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 143: ...Troubleshooting 143 ...
Page 145: ...Troubleshooting 145 ...
Page 147: ...Troubleshooting 147 ...
Page 150: ...150 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 292: ......