Troubleshooting
257
1615-Power Supply Failure, Power Supply Unplugged, or Power
Supply Fan Failure in Bay X
Audible Beeps: None
Possible Cause: The power supply has failed, or it is installed but not connected
to the system board or AC power source.
Action: Reseat the power supply firmly and check the power cable or replace
power supply.
1616-Power Supply Configuration Failure
-A working power supply must be installed in Bay 1 for proper cooling.
-System Halted!
Audible Beeps: None
Possible Cause: Power supply is improperly configured.
Action: Run the server setup utility and correct the configuration.
1700 Series
258
List of messages:
1713-Slot z Drive Array Controller - Redundant ROM Reprogramming Failure......................
1714-Slot z Drive Array Controller - Redundant ROM Checksum Error... ...............................
259
1715-Slot x Drive Array Controller - Memory Error(s) Occurred .............................................
259
1720-Slot X Drive Array - S.M.A.R.T. Hard Drive(s) Detect Imminent Failure SCSI: Port Y:
SCSI ID Z. ..................................................................................................................................
260
1720-S.M.A.R.T. Hard Drive Detects Imminent Failure ...........................................................
260
1721-Slot X Drive Array - Drive Parameter Tracking Predicts Imminent Failure.....................
260
1724-Slot X Drive Array - Physical Drive Position Change(s) Detected - ... ............................
261
1725-Slot X Drive Array-Optional SIMM Failure Detected......................................................
261
1726-Slot X Drive Array - Array Accelerator Memory Size Change Detected. - .....................
261
1727-Slot X Drive Array - New Logical Drive(s) Attachment Detected... ................................
262
1729-Slot 1 Drive Array - Performance Optimization Scan In Progress... ................................
262
1753-Slot z Drive Array - Array Controller Maximum Operating Temperature Exceeded During
Previous Power Up .....................................................................................................................
263
Summary of Contents for ML370 - ProLiant - G3
Page 8: ......
Page 52: ......
Page 85: ...Hardware options installation 85 2 Release the retaining clip 3 Install the expansion board ...
Page 110: ......
Page 130: ......
Page 138: ...138 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 140: ...140 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 143: ...Troubleshooting 143 ...
Page 145: ...Troubleshooting 145 ...
Page 147: ...Troubleshooting 147 ...
Page 150: ...150 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 292: ......