HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide
1777-Slot X Drive Array - ProLiant Drive Storage Enclosure Problem
Detected...
(followed by one or more of the following):
...SCSI Port Y: Cooling Fan Malfunction Detected
SCSI Port Y: Overheated Condition Detected
SCSI Port Y: Side-Panel must be Closed to Prevent Overheating
SCSI Port Y: Redundant Power Supply Malfunction Detected
SCSI Port Y: Wide SCSI Transfer Failed
SCSI Port Y: Interrupt Signal Inoperative
SCSI Port y: Unsupported ProLiant Storage System Detected
Audible Beeps: None
Possible Cause: Environment threshold was violated on the drive enclosure.
Action:
•
•
•
•
•
Check cooling fan operation by placing hand over fan.
Be sure the internal plenum cooling fan in tower servers or storage systems is
operational. If fan is not operating, check for obstructions and check all
internal connections.
Replace unit side panel if removed.
Check the LEDs. If the ProLiant Storage System power LED is amber
instead of green, this indicates a redundant power supply failure.
If the message indicates to check SCSI cables:
a. Compare the cabling against the diagrams in the HP Smart Array
Controller User Guide.
b. If the routing is correct, replace cables on the specified port until the
POST error message is eliminated.
Summary of Contents for ML370 - ProLiant - G3
Page 8: ......
Page 52: ......
Page 85: ...Hardware options installation 85 2 Release the retaining clip 3 Install the expansion board ...
Page 110: ......
Page 130: ......
Page 138: ...138 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 140: ...140 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 143: ...Troubleshooting 143 ...
Page 145: ...Troubleshooting 145 ...
Page 147: ...Troubleshooting 147 ...
Page 150: ...150 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 292: ......