Array Accelerator Battery Pack X Below Reference Voltage (Recharging)
Description: Battery pack on the array accelerator is below the required voltage
levels.
Action: Replace the array accelerator board if the batteries do not recharge
within 36 powered-on hours.
Board in Use by Expand Operation
Description: Array accelerator memory is in use by an expand operation.
Action: Operate the system without the array accelerator board until the expand
operation completes.
Board not Attached
Description: An array controller is configured for use with array accelerator
board, but one is not connected.
Action: Connect array accelerator board to array controller.
Cache Has Been Disabled Because ADG Enabler Dongle is Broken or Missing
Description: The cache has been disabled because RAID ADG volume is
configured but the ADG Enabler Dongle is broken or missing.
Action: Check the ADG Enabler Dongle. Replace if needed.
Cache Has Been Disabled; Likely Caused By a Loose Pin on One of the RAM
Chips
Description: Cache has been disabled due to a large number of ECC errors
detected while testing the cache during POST. Likely caused by a loose pin on
one of the RAM chips.
Action: Try reseating the cache to the controller. If that does not work, replace
the cache.
Summary of Contents for ML370 - ProLiant - G3
Page 8: ......
Page 52: ......
Page 85: ...Hardware options installation 85 2 Release the retaining clip 3 Install the expansion board ...
Page 110: ......
Page 130: ......
Page 138: ...138 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 140: ...140 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 143: ...Troubleshooting 143 ...
Page 145: ...Troubleshooting 145 ...
Page 147: ...Troubleshooting 147 ...
Page 150: ...150 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 292: ......