Troubleshooting
245
209-RAID Memory Configuration - Memory Sizes on boards X and Y
do not match
Audible Beeps: 1 long, 1 short
Possible Cause: The overall size of two boards participating in a RAID do not
match.
Action: Install or reinstall DIMMs to support RAID mode.
210-Memory Board Power Fault on board X
Audible Beeps: 1 long, 1 short
Possible Cause: A problem exists with a memory board powering up properly.
Action: Exchange DIMMs and retest. Replace the memory board if problem
persists.
210-Memory Board Failure on board X
Audible Beeps: 1 long, 1 short
Possible Cause: A problem exists with a memory board powering up properly.
Action: Exchange DIMMs and retest. Replace the memory board if problem
persists.
212-Processor Failed, Processor X
Audible Beeps: 1 short
Possible Cause: Processor in slot X failed.
Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page
126
) and
replace failed components as indicated.
Summary of Contents for ML370 - ProLiant - G3
Page 8: ......
Page 52: ......
Page 85: ...Hardware options installation 85 2 Release the retaining clip 3 Install the expansion board ...
Page 110: ......
Page 130: ......
Page 138: ...138 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 140: ...140 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 143: ...Troubleshooting 143 ...
Page 145: ...Troubleshooting 145 ...
Page 147: ...Troubleshooting 147 ...
Page 150: ...150 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 292: ......