Troubleshooting
157
If the server works with the device removed and uninstalled, either a problem
exists with the device, the server does not support the device, or a conflict
exists with another device.
2. If the device is the only device on a bus, be sure the bus works by installing a
different device on the bus.
3. Restarting the server each time to determine if the device is working, move
the device:
a. To a different slot on the same bus (not applicable for PCI Express)
b. To a PCI, PCI-X, or PCI Express slot on a different bus
c. To the same slot in another working server of the same or similar design
If the board works in any of these slots, either the original slot is bad or the
board was not properly seated. Reinsert the board into the original slot to
verify.
4. If you are testing a board (or a device that connects to a board):
a. Test the board with all other boards removed.
b. Test the server with only that board removed.
CAUTION: Clearing NVRAM deletes the configuration
information. Refer to the server documentation for complete instructions
before performing this operation or data loss could occur.
5. Clearing NVRAM can resolve various problems. Clear the NVRAM, but do
not use the backup .SCI file if prompted. Have available any .CFG, .OVL, or
.PCF files that are required.
Internal system problems
List of problems:
CD-ROM and DVD drive problems...........................................................................................
158
DAT drive problems...................................................................................................................
159
Diskette drive problems..............................................................................................................
160
DLT drive problems ...................................................................................................................
161
Fan problems ..............................................................................................................................
164
Hard drive problems ...................................................................................................................
165
Memory problems.......................................................................................................................
167
PPM problems ............................................................................................................................
169
Summary of Contents for ML370 - ProLiant - G3
Page 8: ......
Page 52: ......
Page 85: ...Hardware options installation 85 2 Release the retaining clip 3 Install the expansion board ...
Page 110: ......
Page 130: ......
Page 138: ...138 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 140: ...140 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 143: ...Troubleshooting 143 ...
Page 145: ...Troubleshooting 145 ...
Page 147: ...Troubleshooting 147 ...
Page 150: ...150 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 292: ......