Troubleshooting
223
Unable to Retrieve Identify Controller Data. Controller May be Disabled or Failed
...SOLUTION: Power down the system. Verify that the controller is fully seated. Then
power the system on and look for helpful error messages displayed by the controller. If this
doesn’t help, contact your COMPAQ service provider.
Description: ADU requested the identify controller data from the controller but
was unable to obtain it. This usually indicates that the controller is not seated
properly or has failed.
Action:
1. Power down the server.
2. Be sure the controller is fully seated.
3. Restart the server.
4. Resolve any error messages displayed by the controller.
If this does not solve the problem, contact an authorized service provider.
Unknown Disable Code
Description: A code was returned from the array accelerator board that ADU
does not recognize.
Action: Obtain the latest version of ADU.
Unrecoverable Read Error
Description: Read parity errors were detected when an attempt to read the same
data from both sides of the mirrored memory was made. Data loss will occur.
Action: Replace the array accelerator board.
Warning Bit Detected
Description: A monitor and performance threshold violation may have occurred.
The status of a logical drive may not be OK.
Action: Check the other error messages for an indication of the problem.
Summary of Contents for ML370 - ProLiant - G3
Page 8: ......
Page 52: ......
Page 85: ...Hardware options installation 85 2 Release the retaining clip 3 Install the expansion board ...
Page 110: ......
Page 130: ......
Page 138: ...138 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 140: ...140 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 143: ...Troubleshooting 143 ...
Page 145: ...Troubleshooting 145 ...
Page 147: ...Troubleshooting 147 ...
Page 150: ...150 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 292: ......