Troubleshooting
275
•
When powering down the system, the server must be powered down before
external storage systems.
1792-Drive Array Reports Valid Data Found in Array Accelerator...
...Data will automatically be written to drive array.
Audible Beeps: None
Possible Cause: Power was interrupted while data was in the array accelerator
memory. Power was then restored within several days, and the data in the array
accelerator was flushed to the drive array.
Action: No action is required. No data has been lost. Perform orderly system
shutdowns to avoid leaving data in the array accelerator.
1793-Drive Array - Array Accelerator Battery Depleted - Data Lost.
(Error message 1794 also displays.)
Audible Beeps: None
Possible Cause: Power was interrupted while data was in the array accelerator
memory, or the array accelerator batteries failed. Data in array accelerator has
been lost.
Action: No action is required. Power was not restored within enough time to
save the data. Perform orderly system shutdowns to avoid leaving data in the
array accelerator.
1794-Drive Array - Array Accelerator Battery Charge Low...
...Array Accelerator is temporarily disabled.
Array Accelerator will be re-enabled when battery reaches full charge.
Summary of Contents for ML370 - ProLiant - G3
Page 8: ......
Page 52: ......
Page 85: ...Hardware options installation 85 2 Release the retaining clip 3 Install the expansion board ...
Page 110: ......
Page 130: ......
Page 138: ...138 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 140: ...140 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 143: ...Troubleshooting 143 ...
Page 145: ...Troubleshooting 145 ...
Page 147: ...Troubleshooting 147 ...
Page 150: ...150 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Page 292: ......