SCSI HBA 449
Table 18-75
HPSCSI_DeviceIndication: Power Supply status DEGRADED
Property name
Property implementation
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
18.4.15Temperature Sensor Status Change OK
Note: This indication may not be generated due to the SCSI firmware does not report this indication
Table 18-76
HPSCSI_DeviceIndication: Temperature sensor status change OK
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID
string
generated at time of indication
PerceivedSeverity 2
(Info)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Temperature sensor status
changed from non-OK to OK.
AlertingMangedElement
WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2
(CIMObjectPath)
AlertType
5 (Device Alert)
EventID 307
EventTime
Time of the event or time of the indication if event time
unknown.
ProviderName HP
SCSI
RecommendedActions No
action is recommended.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Temperature sensor status OK
EventCategory
24 (Primary Storage Cooling)
ProbableCause 1
(Other)
ProbableCauseDescription
Temperature Status Changed to OK
ProviderVersion
Provider version generating the indication, in the form:
major.minor.revision.build
.