SAS HBA 367
Table 17-76
HPSAS_DeviceIndication: Physical Drive status REBUILDING
Property name
Property implementation
PreceivedSeverity Severity
For example, 2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A physical drive status has changed to Rebuilding.
Data is now being rebuilt onto this drive from the RAID
set.
AlertingMangedElement
WBEM Path of disk drive
AlertingElementFormat 2
(CIMObjectPath)
AlertType
5 (Device Alert)
EventID 203
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName HP
SAS
RecommendedActions No
action is recommended.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Physical
drive
rebuilding
EventCategory
6 (Primary Storage)
ProbableCause 1
(Other)
ProbableCauseDescription Physical
Drive
Rebuilding
ProviderVersion
Provider version generating the indication, in the form:
major.minor.revision.build
.
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
•
69 (Windows Server 2003 32-bit)
OSType
•
70 (Windows Server 2003 64-bit)
•
77 (Windows Server 2008 32-bit)
•
77 (Windows Server 2008 64-bit)
•
103 (Windows Server 2008 R2)
OSVersion
The operating system version of the computer system
generating the indication in the following format:
major
.
minor
.
build
SystemFirmwareVersion Firmware
version
of the computer system generating
the indication