Smart Array 240
Table 15-100
HPSA_DeviceIndication: Physical Drive status changed to OK
Property name
Property implementation
•
VariableNames[0]: FailureDescription
VariableNames
•
VariableNames[1]: LastFailureDescription
•
VariableNames[2]: DriveInterface
•
VariableTypes[0]: 1 (String)
VariableTypes
•
VariableTypes[1]: 1 (String)
•
VariableTypes[2]: 4 (uint16)
•
VariableValues[0]: Short Description of failure
VariableValues
•
VariableValues[1]: Short Description of last failure
•
VariableValues[2]: HPSA_DiskDrive.DriveInterface
•
3 (Enclosure) for c-Class blade systems
ImpactedDomain
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional
property containing the virtual system
serial number string when running in a Virtual Connect
environment.
SystemVirtualUUID Conditional
property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
HWFirmwareVersion Physical
Disk firmware version string
HWLogicalLocation
Physical Disk Location string
For example, Port:1E Box: 1 Bay: 5
HWPhysicalLocation
Physical Location of the Failed Drive (Bay Number)
DeviceControllerLogicalLocation Controller
Location
For example, SmartArray 642 in Slot 2
HWManufacturer Compaq
HWSerialNumber
Physical Disk Serial Number
HP_DeviceInd
i
cation
DeviceModel
Physical Disk Model string