Ethernet Teaming 156
Table 13-24
Class: HP+EthEventSettings
Property name
Property implementation
MemberRoleChanged
If enabled, an event is generated when any change in
team member role is detected. Default: disabled.
MemberStatusChanged
If enabled, an event is generated when any change in
team member status is detected. Default: disabled.
MonitorLANEndpoints
If enabled, events related to HP_WinEthLANEndpoint
are generated. Default: disabled.
MonitorPorts
If enabled, events related to HP_WinEthernetPort are
generated. Default: enabled.
MonitorRedundancySets
If enabled, events related to HP_WinEthRedundancySet
are generated. Default: true.
PolInterval
The longest interval between network status polls, in
seconds. Value 0 disables polling and is not
recommended. Using very low values can increase
CPU utilization. Default: 200.
13.4
Supported indications
The following indications are implemented for Integrity server platforms where available. System
Ethernet Port, Ethernet Team, and Ethernet LAN Endpoint indications are described in the following.
For nonteamed Ethernet Ports, if the associated HP_EthernetMemberOfCollection.Included is False, the
following indications are disabled.
For teamed Ethernet Ports, this association does not exist. For Ethernet Teams where the association
does exist, but the Included property value is ignored, all applicable indications are enabled.
13.4.1Ethernet Team Redundancy Lost
Table 13-25
HP_AlertIndication: Ethernet Team Redundancy Lost
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID
string generated at indication
PerceivedSeverity 6
(Critical)
IndicationTime
Time of indication
CIM_AlertIndication
Description
An Ethernet team's redundancy status changed to
Redundancy Lost. All members of an Ethernet team,
except one, are failed.
AlertingManagedElement
WBEM path of the Ethernet Team (HP_EthernetTeam)
reporting lost redundancy
AlertingElementFormat 2
(CIMObjectPath)