System Power Supply 59
4.3.13HP_SystemPhysicalPowerSupply
HP_SystemPhysicalPowerSupply is used to represent an association between HP_PowerSupplyModule
and the computer system that contains this power supply.
Table 4-14
Class: HP_SystemPhysicalPowerSupply
Property name
Property implementation
GroupComponent References
HP_ComputerSystemChassis
PartComponent References
HP_PowerSupplyModule
4.3.14HP_PowerMeter
HP_PowerMeter is used to model the power consumption within power supplies on Integrity Servers.
The Windows specific implementation class is HP_WinPowerMeter. Not all systems support reporting
power consumption information. Note: Power supply numbers for existing instances do not change
when other power supplies are added and removed.
Table 4-15
Class: HP_PowerMeter
Property name
Property implementation
CIM_ManagedElement
Caption Power
Meter
n
, where
n
represents the number of the
power meter instance.
Description Power
Meter
n
provides power monitoring for Power
Suply
m
, where
n
represents the number of the power
meter instance and
m
represents the power supply
instance.
ElementName Power
Meter
n
, where
n
represents the number of the
power meter instance.
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) – if power consumption reported by the sensor
is within normal operating range
Power consumption reported by the sensor
is within normal operating range
– if
temperature reported by the sensor is within normal
operating range.
StatusDescriptions[0]
HealthState
5 (OK) – if power supply is operating properly
Name Power
Supply
n
, where
n
is the physical bay number.
CIM_LogicalDevice
CreationClassName HP_
WinPowermeter
DeviceID
Unique identifier for this power meter instance.