SCSI HBA 447
Table 18-74
HPSCSI_DeviceIndication: Power Supply status OK
Property name
Property implementation
HP_DeviceIndication
DeviceModel
Enclosure Model string
18.4.14Power Supply Status DEGRADED
Note: This indication might not be generated because the SCSI firmware does not report this
indication.
Table 18-75
HPSCSI_DeviceIndication: Power Supply status DEGRADED
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID
string
generated at time of indication
PerceivedSeverity 3
(Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Power Supply status has changed
to Degraded Redundancy.
AlertingMangedElement
WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2
(CIMObjectPath)
AlertType
5 (Device Alert)
EventID 303
EventTime
Time of the event or time of the indication if event time
unknown.
ProviderName HP
SCSI
RecommendedActions
Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Power supply status Redundant Degraded
EventCategory
17 (Primary Storage Power)
ProbableCause
89 (Power Supply Failure)
ProbableCauseDescription
Redundant Power Supply Degraded