SAS HBA 369
17.4.6Drive Status PREDICTIVE FAILURE
Table 17-77
HPSAS_DeviceIndication: Drive status PREDICTIVE FAILURE
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PreceivedSeverity 5
(Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A physical drive status has changed to Predictive
Failure.
AlertingMangedElement
WBEM Path of disk drive
AlertingElementFormat 2
(CIMObjectPath)
AlertType
5 (Device Alert)
EventID 204
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName HP
SAS
RecommendedActions
Replace drive immediately to avoid loss of data.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical drive predictive failure
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
ProbableCauseDescription
Physical Drive Predictive Failure
ProviderVersion
Provider version generating the indication, in the form:
major.minor.revision.build
.
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
•
69 (Windows Server 2003 32-bit)
OSType
•
70 (Windows Server 2003 64-bit)
•
77 (Windows Server 2008 32-bit)
•
77 (Windows Server 2008 64-bit)
•
103 (Windows Server 2008 R2)
OSVersion
The operating system version of the computer system
generating the indication in the following format:
major
.
minor
.
build