SAS HBA 368
Table 17-76
HPSAS_DeviceIndication: Physical Drive status REBUILDING
Property name
Property implementation
SystemSerialNumber
Serial number of the computer system generating the
indication
SystemProductID
Product ID of the computer system generating the
indication
SystemModel
Model name of the computer system generating the
indication
SystemGUID
Platform GUID of the computer system generating the
indication
VariableNames FailureDescription
VariableTypes 1
(String)
VariableValues
Short Description of failure
In some cases, VariableValues can be N/A or “” (null).
•
3 (Enclosure) for c-Class blade systems
ImpactedDomain
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional
property containing the virtual system
serial number string when running in a Virtual Connect
environment.
SystemVirtualUUID Conditional
property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
HWFirmwareVersion Disk
firmware version string
HWLogicalLocation
Disk Location string
For example, Bay 3
HWManufacturer
Disk Manufacturer string
HWSerialNumber
Disk Serial Number
HP_DeviceIndication
DeviceModel
Disk Model string