Smart Array 252
Table 15-106
HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity 3
(Degraded)
IndicationTime
Time of indication
CIM_AlertIndication
Description
Logical Drive is in a degraded state. Device is still
servicing I/O but redundancy may be degraded or
lost.
AlertingMangedElement
WBEM path of the HPSA_StorageVolume class
AlertingElementFormat 2
(CIMObjectPath)
AlertType
5 (Device Alert)
EventID 103
ProviderName HP
SmartArray
RecommendedActions
Check status of physical drives. Degraded status may
be caused by failed or missing physical drives, or a
data recovery operation on one or more physical
drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Logical Drive in degraded state.
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
NetworkAddresses
A list of all the IP addresses (IPV4 and IPv6) of the
computer system generating the indication
•
70 (Windows Server 2003 64-bit)
OSType
•
77 (Windows Server 2008 64-bit)
•
103 (Windows Server 2008 R2)
OSVersion
Operating system version of the computer system
generating the indication in the format,
major
.
minor
.
build
ProviderVersion
Provider version generating the information, in the
form:
major.minor.revision.build
.
SystemFirmwareVersion Firmware
version
of the computer system generating
the indication
SystemSerialNumber
Serial number of the computer system generating the
indication