Smart Array 250
Table 15-105
HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR
Property name
Property implementation
AlertingElementFormat 2
(CIMObjectPath)
AlertType
5 (Device Alert)
EventID 102
EventTime
Time of the event or time of the indication if event time
unknown.
ProviderName HP
SmartArray
RecommendedActions
Check for failed or removed physical drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Logical drive status error
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
ProbableCauseDescription
Logical Drive Status Changed to Error
NetworkAddresses
A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
•
70 (Windows Server 2003 64-bit)
OSType
•
77 (Windows Server 2008 64-bit)
•
103 (Windows Server 2008 R2)
OSVersion
Operating system version of the computer system
generating the indication in the format,
major
.
minor
.
build
ProviderVersion
Provider version generating the information, in the
form:
major.minor.revision.build
.
SystemFirmwareVersion Firmware
version
of the computer system generating
the indication
SystemSerialNumber
Serial number of the computer system generating the
indication
SystemProductID
Product ID of the computer system generating the
indication
SystemModel
Model name of the computer system generating the
indication
SystemGUID
Platform GUID of the computer system generating the
indication
VariableNames FailureDescription
VariableTypes 1
(String)