System fan 64
Table 5-2
Class: HP_Fan
Property name
Property implementation
Caption
Fan
n:Location
, where
n
represents the number of
the fan instance. For example:
FAN 10:cabinet 0
- fan 0
Description
Fan
n:Location
provides cooling for
fantype
.
statusdescription
, where
n
represents the
number of the fan instance,
fantype
represents the
corresponding string value of the FanType
enumeration, and
s
tatusdescription
represents the value
of StatusDescriptions[0].
Example:
FAN 10:cabinet 0 - fan 0 provides
cooling for System board. Fan is
operating properly.
ElementName
Fan
n:Location
CIM_ManagedSystemElement
•
2 (OK)—if fan is operating properly;
OperationalStatus[0]
•
6 (Error)—if fan has failed
•
Fan is operating properly—if OperationalStatus[0]
is 2 (OK)
StatusDescriptions[0]
•
Fan has failed—if OperationalStatus is 6 (Error)
•
5 (OK)—if fan is operating properly
HealthState
•
20 (Major Failure)—if fan has failed
Name
Fan
n
, where
n
represents the number of the fan
instance.
CIM_LogicalDevice
CreationClassName HP_WinFan
DeviceID
Fan
n
, where
n
represents a unique identifier for this
fan instance
SystemCreationClassName HP_ComputerSystem.CreationClassName
SystemName HP_ComputerSystem.Name
CIM_EnabledLogicalElement
EnabledDefault 2
(Enabled)
EnabledState
5 (Not Applicable)
RequestedState
12 (Not Applicable)
CIM_CoolingDevice
ActiveCooling True
CIM_Fan
•
True—if fan supports variable speed
VariableSpeed
•
False—if fan does not support variable speed or is
unknown