SAS HBA 374
Table 17-79
HPSAS_DeviceIndication: Logical Drive status ERROR
Property name
Property implementation
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional
property containing the virtual system
serial number string when running in a Virtual Connect
environment.
SystemVirtualUUID Conditional
property containing the virtual system
UUID when running in a Virtual Connect environment.
17.4.9Logical Drive is in a Degraded State
Table 17-80
HPSAS_DeviceIndication: Logical Drive is in a degraded state
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PreceivedSeverity 3
(Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A logical drive is in a degraded state. Device is still
servicing I/O, but redundancy may be degraded or
lost.
AlertingMangedElement
WBEM Path of Storage Volume
AlertingElementFormat 2
(CIMObjectPath)
AlertType
5 (Device Alert)
EventID 103
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName HP
SAS
RecommendedActions
Check status of physical drives. Degraded status may
be caused by failed or missing physical drives, or a
data recovery operation on one or more physical
drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication