System fan 68
5.3.5HP_HostedCoolingRedundancySet
HP_HostedCoolingRedundancySet is used to represent an association between
HP_CoolingRedundancySet and the computer system that contains this redundancy set. The Windows
implementation class is HP_WinHostedCoolingRedundancySet.
Table 5-6
Class: HP_HostedCoolingRedundancySet
Property name
Property implementation
OwningElement References
HP_ComputerSystem
OwnedElement References
HP_CoolingRedundancySet
5.3.6HP_MemberOfCoolingCollection
HP_MemberOfCoolingCollection is used to represent an association between HP_Fan and
HP_CoolingCollection. The Windows implementation class is HP_WinMemberOfCoolingCollection.
Table 5-7
Class: HP_MemberOfCoolingCollection
Property name
Property implementation
Collection References
HP_CoolingCollection
Member References
HP_Fan
5.3.7HP_HostedCoolingCollection
HP_HostedCoolingCollection is used to represent an association between HP_CoolingCollection and
the computer system that contains this collection. The Windows implementation class is
HP_WinHostedCoolingCollection.
Table 5-8
Class: HP_HostedCoolingCollection
Property name
Property implementation
Antecedent References
HP_ComputerSystem
Dependent References
HP_CoolingCollection
5.3.8HP_SystemFan
HP_SystemFan is used to represent an association between HP_Fan and the computer system that
contains this fan. The Windows implementation class is HP_WinSystemFan.
Table 5-9
Class: HP_SystemFan
Property name
Property implementation
GroupComponent References
HP_ComputerSystem