Smart Array 245
Table 15-102
HPSA_DeviceIndication: Physical Drive status changed to REBUILDING
Property name
Property implementation
HWLogicalLocation
Physical Disk Location string
For example, Port:1E Box: 1 Bay: 5
HWPhysicalLocation
Physical Location of the Failed Drive (Bay Number)
DeviceControllerLogicalLocation Controller
location
For example, SmartArray 642 in Slot 2
HWManufacturer Compaq
HWSerialNumber
Physical Disk Serial Number
HP_DeviceIndication
DeviceModel
Physical Disk Model string
15.4.4Physical Drive Status Changed to PREDICTIVE FAILURE
Table 15-103
HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity 5
(Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A physical drive status has changed to Predictive
Failure.
AlertingMangedElement
WBEM path of the HPSA_DiskDrive class
AlertingElementFormat 2
(CIMObjectPath)
AlertType
5 (Device Alert)
EventID 204
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName HP
SmartArray
RecommendedActions
Replace drive immediately to avoid loss of data.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical drive status Predictive Failure.
EventCategory
6 (Primary Storage)