Smart Array 295
15.4.27Enclosure Fan Status Changed to Failure
Table 15-126
HPSA_DeviceIndication: Enclosure Fan status changed to Failure
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID
string
generated at time of indication
PerceivedSeverity 5
(major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Fan status changed to Failure. An
enclosure has detected a failure in the fan subsystem
and there is insufficient fan capability to ensure normal
operation.
AlertingMangedElement
WBEM path of the HPSA_StorageEnclosureProcessor
AlertingElementFormat 2
(CIMObjectPath)
AlertType
5 (Device Alert)
EventID 306
ProviderName
HP Smart Array
RecommendedActions
Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Fan status Error.
EventCategory
24 (Primary Storage Cooling)
ProbableCause
94 (Fan failure)
ProbableCauseDescription Fan
Failure
NetworkAddresses
A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication.
•
69 (Windows Server 2003 32-bit)
OSType
•
70 (Windows Server 2003 64-bit)
•
76 (Windows Server 2008 32-bit)
•
77 (Windows Server 2008 64-bit)
•
103 (Windows Server 2008 R2)
OSVersion
Operating system version of the computer system
generating the indication in the format,
major
.
minor
.
build