Smart Array 241
15.4.2Physical Drive Status Changed to ERROR
Table 15-101
HPSA_DeviceIndication: Physical Drive status changed to ERROR
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity Severity:
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
A physical drive status has changed to
Error.
Description
AlertingMangedElement
WBEM path of the HPSA_DiskDrive class
AlertingElementFormat 2
(CIMObjectPath)
AlertType
5 (Device Alert)
EventID 202
EventTime
Time of the event or time of the indication if event time
unknown.
ProviderName HP
SmartArray
RecommendedActions
Check for failed or removed physical drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical drive status Error.
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
ProbableCauseDescription Physical Drive Status Changed to Error
NetworkAddresses
A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
•
70 (Windows Server 2003 64-bit)
OSType
•
77 (Windows Server 2008 64-bit)
•
103 (Windows Server 2008 R2)
OSVersion
Operating system version of the computer system
generating the indication in the format,
major
.
minor
.
build
ProviderVersion
Provider version generating the information, in the
form:
major.minor.revision.build
.
SystemFirmwareVersion Firmware
version
of the computer system generating
the indication