SCSI HBA 424
Table 18-62
HPSCSI_DeviceIndication: Physical Drive status set to OK
Property name
Property implementation
HWManufacturer
Disk Manufacturer string
HWSerialNumber
Disk Serial Number
HP_DeviceIndication
DeviceModel
Disk Model string
18.4.2Physical Drive Status Set to ERROR
Table 18-63
HPSCSI_DeviceIndication: Physical Drive status set to ERROR
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID
string
generated at time of indication
PerceivedSeverity
Severity (for example, 5 (Major))
IndicationTime
Time of indication
CIM_AlertIndication
Description
A SCSI physical drive has a status of Error.
AlertingMangedElement
WBEM path of the HPSCSI_DiskDrive class instance
AlertingElementFormat 2
(CIMObjectPath)
AlertType
5 (Device Alert)
EventID 5
EventTime
Time of the event or time of the indication if event time
unknown.
ProviderName HP
SCSI
RecommendedActions
Check for failed or removed physical drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical drive ERROR.
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
ProbableCauseDescription Physical
Drive
Error
ProviderVersion
Provider version generating the indication, in the form:
major.minor.revision.build
.
NetworkAddresses
A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication