SCSI HBA 426
18.4.3Physical Drive Status is Set to Predictive Failure
Table 18-64
HPSCSI_DeviceIndication: Physical Drive status is set to Predictive Failure
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID
string
generated at time of indication
PerceivedSeverity 5
(Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A SCSI physical drive status is now set to Predictive
Failure.
AlertingMangedElement
WBEM path of the HPSCSI_DiskDrive class instance
AlertingElementFormat 2
(CIMObjectPath)
AlertType
5 (Device Alert)
EventID 8
EventTime
Time of the event or time of the indication if event time
unknown.
ProviderName HP
SCSI
RecommendedActions
Replace drive immediately to avoid loss of data.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
SCSI physical drive predictive failure.
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
ProbableCauseDescription
SCSI Physical Drive Predictive Failure
ProviderVersion
Provider version generating the indication, in the form:
major.minor.revision.build
.
NetworkAddresses
A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
•
69 (Windows Server 2003 32-bit)
OSType
•
70 (Windows Server 2003 64-bit)
•
76 (Windows Server 2008 32-bit)
•
77 (Windows Server 2008 64-bit)
•
103 (Windows Server 2008 R2)
OSVersion
Operating system version of the computer system
generating the indication in the format,
major
.
minor
.
build