Smart Array 257
Table 15-108
HPSA_DeviceIndication: Controller status changed to ERROR
Property name
Property implementation
Summary
Controller status Error
EventCategory
6 (Primary Storage)
ProbableCause
24 (I/O device error)
ProbableCauseDescription
Array Controller Status Changed to Error
NetworkAddresses
A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
•
70 (Windows Server 2003 64-bit)
OSType
•
77 (Windows Server 2008 64-bit)
•
103 (Windows Server 2008 R2)
OSVersion
Operating system version of the computer system
generating the indication in the format,
major
.
minor
.
build
ProviderVersion
Provider version generating the information, in the
form:
major.minor.revision.build
.
SystemFirmwareVersion Firmware
version
of the computer system generating
the indication
SystemSerialNumber
Serial number of the computer system generating the
indication
SystemProductID
Product ID of the computer system generating the
indication
SystemModel
Model name of the computer system generating the
indication
SystemGUID
Platform GUID of the computer system generating the
indication
•
VariableNames[0]: FailureDescription
VariableNames
•
VariableNames[1]: CacheSizeTotal
•
VariableNames[2]: CacheSerialNumber
•
VariableTypes[0]: 1 (String)
VariableTypes
•
VariableTypes[1]: 5 (uint16)
•
VariableTypes[2]: 1 (String)
•
VariableValues[0]: Short Description of failure
VariableValues
•
VariableValues[1]:
HPSA_ArrayController.CacheSizeTotal
•
VariableValues[2]:
HPSA_ArrayController.CacheSerialNumber
Note: In some cases the VariableValues property can
be
N/A
or
""
(null).
•
3 (Enclosure) for c-Class blade systems
ImpactedDomain
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.