SAS HBA 390
17.4.17Enclosure Fan Status Changed to Degraded
Table 17-88
HPSAS_DeviceIndication: Enclosure Fan status changed to Degraded
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity 3
(Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Fan status has changed to
Degraded. An enclosure has detected there may a
problem with one or more of the fans.
AlertingMangedElement WBEM
Path
of HPSAS_StorageEnclosureProcessor
AlertingElementFormat 2
(CIMObjectPath)
AlertType
5 (Device Alert)
EventID 305
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName HP
SAS
RecommendedActions
Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndicatio
n
Summary
Fan status Degraded
EventCategory
24 (Primary Storage Cooling)
ProbableCause
94 (Fan failure)
ProbableCauseDescription Fan
Degraded
ProviderVersion
Provider version generating the indication, in the form:
major.minor.revision.build
.
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
•
69 (Windows Server 2003 32-bit)
OSType
•
70 (Windows Server 2003 64-bit)
•
77 (Windows Server 2008 32-bit)
•
77 (Windows Server 2008 64-bit)
•
103 (Windows Server 2008 R2)