SAS HBA 384
17.4.14Enclosure Temperature Status Changed to Warning
Table 17-85
HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity 3
(Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Temperature sensor Status
changed to Warning Condition. This indicates the
enclosure temperature is above normal, otherwise
enclosure is still operating normally.
AlertingMangedElement WBEM
Path
of HPSAS_StorageEnclosureProcessor
AlertingElementFormat 2
(CIMObjectPath)
AlertType
5 (Device Alert)
EventID 308
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName HP
SAS
RecommendedActions
Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Temperature sensor status Warning Condition
EventCategory
24 (Primary Storage Cooling)
ProbableCause
51 (Temperature Unacceptable)
ProbableCauseDescription Temperature
Status Changed to Warning Condition
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
•
69 (Windows Server 2003 32-bit)
OSType
•
70 (Windows Server 2003 64-bit)
•
77 (Windows Server 2008 32-bit)
•
77 (Windows Server 2008 64-bit)
•
103 (Windows Server 2008 R2)