SAS HBA 392
17.4.18Enclosure Fan Status Changed to Failure
Table 17-89
HPSAS_DeviceIndication: Enclosure Fan status changed to Failure
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity 5
(major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Fan Status changed to Failure. An
enclosure has detected a failure in the fan subsystem
and there is insufficient fan capability to ensure normal
operation.
AlertingMangedElement WBEM
Path
of HPSAS_StorageEnclosureProcessor
AlertingElementFormat 2
(CIMObjectPath)
AlertType
5 (Device Alert)
EventID 306
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName HP
SAS
RecommendedActions
Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Fan status Error
EventCategory
24 (Primary Storage Cooling)
ProbableCause
94 (Fan failure)
ProbableCauseDescription Fan
Failure
ProviderVersion
Provider version generating the indication, in the form:
major.minor.revision.build
.
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
•
69 (Windows Server 2003 32-bit)
OSType
•
70 (Windows Server 2003 64-bit)
•
77 (Windows Server 2008 32-bit)
•
77 (Windows Server 2008 64-bit)
•
103 (Windows Server 2008 R2)