System fan 70
Table 5-10
Class: HP_FanModule
Property name
Property implementation
PackageType 7
(Fan)
•
3 (Removable when off)
RemovalConditions
•
4 (Removable when on or off)
HP_Fan
5.3.10HP_FanSlot
HP_FanSlot represents fan slot on Integrity Servers. There will be an instance of this class for each fan
slot in the system (whether the slot is occupied or not).
Table 5-11
Class: HP_FanModule
Property name
Property implementation
CIM_ManagedElement
Caption
Fan
n
, where
n
is the physical slot number.
CIM_ManagedSystemElement
•
5 (OK) – if fan is operating properly
HealthState
•
20 (Major Failure) – if fan has failed
Name
Fan
n
, where
n
is the physical slot number.
•
2 (OK) – if fan is operating properly;
OperationalStatus[0]
•
6 (Error) – if fan has failed
StatusDescription[0]
•
Fan is operating properly
– if
OperationalStatus[0] is 2 (OK)
•
Fan has failed
– if OperationalStatus is 6
(Error)
CIM_PhysicalElement
CreationClassName HP_FanSlot
Tag
Fan
n
, where
n
is the physical slot number.
Description
Fan
n
, where
n
is the physical slot number.
ElementName
Fan
n
, where
n
is the physical slot number.
CIM_PhysicalConnector
ConnectorLayout 7
(Slot)
ConnectorPinout
Custom Fan Slot
ConnectorType
76 (Proprietary) – Custom Fan slot
CIM_Slot
Number
The physical fan slot number.