3-2. Adjustable Components
Reference
Designator
Adjustment
Name
ZHF GAIN
INT GAIN
FOCUS COMP
FOC
CTR
FOC
CTR
ORTHO
3 D
INTENSITY
LIMIT
ASTIG
FOCUS LIMIT
X POSN
X GAIN
XHF GAIN
Cl04
Cl09
Y POSN
Y GAIN
YHF GAIN
+ 15 ADJ
HV ADJUST
Adjustment
Number
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
1
2
Adjustment Function
Adjusts rise and fall times of Z axis amplifier pulse.
Adjusts rise and fall times of Z axis amplifier pulse.
Sets adjustment range of front-panel INTENSITY
control.
Corrects focus for beam intensity.
Magnitude of top/bottom focus correction.
Centering of top/bottom focus correction.
Magnitude of right/left focus correction.
Centering of right/left focus correction.
Sets
of CRT.
Adjusts spot size.
Sets adjustment range of front-panel INTENSITY
control.
Adjusts astigmatism of CRT.
Coarse adjusts CRT focus.
Adjusts rise and
times of X deflection amplifier
pulse.
Adjusts rise and fall times of X deflection amplifier
pulse.
Adjusts horizontal position of trace.
Adjusts horizontal gain of trace.
Adjusts rise and
times or X deflection amplifier
pulse.
Adjusts rise and fall times of Y deflection amplifier
pulse.
Adjusts rise and fall times of Y deflection amplifier
pulse.
Adjusts vertical position of trace.
Adjusts vertical gain of trace.
Adjusts rise and
times of Y deflection amplifier
pulse.
A 15 V dc supply voltage.
Adjusts CRT high voltage.
Serial Prefix 3001A and below,
see back of table for
exceptions to
through AlA6.
Adjustments 3-5