Keyboard
Z-Axis Amplifier
X-Deflection Amplifier
Y-Deflection Amplifier
Adjustment 2, “High-Voltage Adjustment,” should be performed before
performing the following adjustment procedure.
Perform this adjustment only if components have been replaced on
the
Z-Axis Amplifier,
X-Deflection Amplifier, or
Amplifier Assemblies. Components
HF GAIN,
HF GAIN,
HF
GAIN,
and
are factory adjusted and normally do
not require readjustment.
The Al Display Section is adjusted to compensate the CRT drive
circuits for proper horizontal and vertical characteristics. These
preliminary adjustments are necessary only when a major repair has
been performed in the display section (for example, replacement or
repair of the
Z Axis Amplifier,
X-Deflection Amplifier, or
Y-Deflection Amplifier assemblies). For routine maintenance,
CRT replacement, or minor repairs, only adjustment procedure 4,
“Final Display Adjustments,” needs to be performed.
Be sure not to allow a high intensity spot to remain on the spectrum
analyzer CRT. A fixed spot of high intensity may permanently damage
the CRT’s phosphor coating. Monitor the CRT closely during the
following adjustment procedures. If a spot occurs, move it off-screen
by adjusting either the front-panel INTENSITY control, or the
horizontal or vertical deflection position controls.
Digitizing Oscilloscope . . . . . . . . . . . . . . . . . . . . . . . . . . . HP 54501A
Pulse/Function Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP 8
Divider Probe, 10 MW7.5
required) . . . . . . . . . . .
HP 10432A
Display Adjustment PC Board
accessory) . . . . . .
Termination, BNC
. . . . . . . . . . . . . . . . . . . . HP 11593A
Adapters:
Adapter, BNC tee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adapter, BNC(f)
to
. . . . . . . . . . . . . . . . . .
Adjustments