C
OMMISSIONING
8029HEPTA-V2/GPS GPS - NTP Time Server with LAN Interface - V08.00
32 / 130
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
6.4
Establish the Network Connection via Web Browser
Ensure that the network parameters of the Time Server 8029HEPTA/GPS
are configured in accordance with the local network before connecting the
device to the network.
Connecting a network to an incorrectly configured Time Server
8029HEPTA/GPS (e.g. duplicate IP address) may cause interference on
the network.
The Time Server 8029HEPTA/GPS is supplied with a static IP-address
(equivalent to the factory default setting).
IP-address:
192.168.0.1
Network mask:
255.255.255.0
Gateway:
not set
In case it is not known whether the Time Server 8029HEPTA/GPS with a
Factory Default setting causes problems in the network, the basis network
parameterization should be executed via a "Peer to Peer" network
connection.
Request the required network parameters from your network administrator
if those are unknown.
The network connection is made via a LAN cable and RJ45 plug (recommended cable type:
CAT5 or better).
6.5
Network Configuration for ETH0 via LAN through
hmc
After connecting the system to the power supply and creating the physical network connection
to LAN interface of the Time Server 8029HEPTA/GPS, the device can be searched for on the
network via the
hmc
(
hopf
Management Console
). Then
the base LAN parameters (IP
address, netmask and gateway or DHCP) may be adjusted in order to allow accessibility of
the Time Server 8029HEPTA/GPS for other systems on the network.
The SEARCH Function of the
hmc
-
Network Configuration Assistant
requires
for location and recognition of the wished Time Server
8029HEPTA/GPS that the
hmc
-computer and the Time Server
8029HEPTA/GPS are
in the same SUB Net
.