3
−
38
Accel/Decel
Standard acceleration and deceleration is
linear. The inverter CPU can also
calculate an S-curve acceleration or
deceleration curve as shown. This profile
is useful for favoring the load
characteristics in particular applications.
Curve settings for acceleration and
deceleration are independently selected.
To enable the S-curve, use function
A097
(acceleration) and
A098
(deceleration).
“A” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
Lnitial data
Units
A097
Acceleration curve selection
Set the characteristic curve of
Acc1 and Acc2, five options:
00
…
linear
01
…
S-curve
02
…
U-curve
03
…
Inverse U-curve
04
…
EL S-curve
Set the characteristic curve of
Dec1 and Dec2, options are
same as above (
a097
)
U
00
−
A098
Deceleration curve selection
U
00
−
a131
Acceleration curve constant
Range is 01 to 10.
Range is 01 to 10.
U
02
−
a132
Deceleration curve constant
U
02
−
a150
Curvature of EL-S-curve at
the start of acceleration
Range is 0 to 50%
U
10. %
a151
Curvature of EL-S-curve at
the end of acceleration
Range is 0 to 50%
U
10. %
a152
Curvature of EL-S-curve at
the start of deceleration
Range is 0 to 50%
U
10. %
a153
Curvature of EL-S-curve at
the end of deceleration
Range is 0 to 50%
U
10. %
See next page for the details.
A097
=
00
Accel. curve selection
Output
frequency
S-curve
Linear
t
0
A097
=
01
Target
freq.
Acceleration period
Summary of Contents for WJ200 Series Software
Page 19: ...xviii Revisions Revision History Table No Revision Comments Date of Issue Operation Manual No ...
Page 295: ...4 92 Safe Stop Function To be finalized after TUV approval ...
Page 296: ...5 1 5 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 ...
Page 322: ...A 1 A Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 ...
Page 378: ...B 49 Note 2 Be sure not to write into above 1F02h to 1F1Dh ...