3
−
54
“b” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
Lnitial data Units
B031
Software lock mode
selection
Prevents parameter changes, in
five options, option codes:
00
…
all parameters except
B031
are locked when [SFT] terminal
is ON
01
…
all parameters except
B031
and
output frequency
F001
are locked
when [SFT] terminal is ON
02
…
all parameters except
B031
are
locked
03
…
all parameters except
B031
and
output frequency
F001
are locked
10
…
High level access including
B031
See appendix C for the accessible
parameters in this mode.
U
01
−
NOTE: To disable parameter editing when using
B031
lock modes
00
and
01
, assign the
[SFT] function to one of the intelligent input terminals.
See “Software Lock” in chapter 4
Motor Cable Length Parameter
To achieve higher motor control performance, the WJ200 inverter has the Motor Cable
Length Parameter setting
B033
. Normally there is no need to adjust this parameter,
however in case of long motor cable and/or shielded cable, where there is a
comparatively higher earth capacitance, set this parameter higher to achieve better
motor control performance.
Note that the parameter is indicative and no formula to calculate the suitable value.
Normally, longer the motor cable, bigger the set value. Please adjust depending on your
system.
For 11 and 15kW inverter, it is not needed to set b033.
“b” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
Lnitial data Units
B033
Motor cable length
parameter
Set range is 5 to 20.
U
10.
−
Summary of Contents for WJ200 Series Software
Page 19: ...xviii Revisions Revision History Table No Revision Comments Date of Issue Operation Manual No ...
Page 295: ...4 92 Safe Stop Function To be finalized after TUV approval ...
Page 296: ...5 1 5 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 ...
Page 322: ...A 1 A Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 ...
Page 378: ...B 49 Note 2 Be sure not to write into above 1F02h to 1F1Dh ...